Back to Tools DirectoryElectricity at Work Regulations 1989 (EAWR) Guide

Machinery Safety Distance & Light Curtain Sizer

Ensure machine movement comes to a complete standstill before an operator can reach the hazardous point of operation. This tool calculates the statutory minimum safety distance S = (K × T) + C under BS EN ISO 13855:2010 and BS EN ISO 13857:2019, factoring in optical beam resolution, stopping times, and brake wear.

Statutory ISO 13855 Approach Speed Rule: Hand approach speed is initially evaluated at K = 2000 mm/s. If the calculated distance exceeds 500 mm, K = 1600 mm/s may be used, provided the final distance does not fall below 500 mm.
1-Click Quick Presets:Tap for instant on-site sizing
Select a preset above to auto-fill common circuit values
1. Safeguard Mechanism & Approach Mode
2. Machine & Safeguard Stopping Time (T)
Machine Braking / Stopping Time (t2)140 ms
Time from trip signal until hazardous motion has completely ceased.
Mechanism: Light Curtain (14mm)Total Time (T): 174 ms
BASIS: BS EN ISO 13855 & ISO 13857S = (2000 × T) + C
Minimum Statutory Safety Distance (S)
348mm
Metric Setback: 0.35 m from dangerous parts
Approach Speed (K)2000 mm/s
Total Time (T)174 ms
Penetration (C)0 mm
Hazard Point348 mm SetbackOptical Plane
0 mm (Danger)500 mm (Speed Knee)1200+ mm
Mathematical Formula Breakdown
S = (2000 × 0.174s) + 0mm
Why Approach Speed (K) Selection Matters:
Why not K = 1600 mm/s? Calculated distance does not exceed 500 mm. Hand approach velocity can reach 2000 mm/s before braking begins, mandating K = 2000 mm/s per ISO 13855.
Site Conditions & Wear AllowancesStandard Parameters (+10% Brake Wear · Shrouded Buttons · 800mm Table)
Show Full Mathematical Derivation (AM2 & Safeguarding Standard)
BS EN ISO 13855:2010
Step-by-step engineering workingTransparent first-principles maths
Step 1 · Total Stopping Performance (T)

System Response & Brake Wear Allowance

T = t1 + (t2 × wear_factor)
20 ms + (140 ms × 1.10) = 174 ms → 0.174 s
BS EN ISO 13855:2010 Clause 5 · Total System Stopping Performance
Step 2 · Penetration Factor (C)

Optical Resolution / Guard Penetration Clearance

C = 8 × (d - 14) for d ≤ 40 mm
8 × (14 mm - 14) → 0 mm
BS EN ISO 13855:2010 Clause 6.2.2 · Table 1
Step 3 · Human Approach Speed (K)

Approach Speed Velocity Evaluation

K = 2000 mm/s (≤ 500mm) or 1600 mm/s (> 500mm)
S initial ≤ 500 mm: K remains 2000 mm/s → 2000 mm/s
BS EN ISO 13855:2010 Clause 6.2.3 · Speed Transition Rule
Step 4 · Minimum Safety Distance (S)

Statutory Safeguard Positioning Distance

S = (K × T) + C
(2000 mm/s × 0.174 s) + 0 mm → 348 mm (0.35 m)
BS EN ISO 13855:2010 Equation 1 · PUWER 1998 Regulation 11
Worked Example & Engineering Rationale: Hydraulic Press

Design Scenario: A hydraulic stamping press is safeguarded by an optical light curtain with 14 mm finger resolution.

  • Controller Response (t1): 20 ms.
  • Hydraulic Valve & Ram Stopping Time (t2): 140 ms with a +10% brake wear factor: 140 × 1.10 = 154 ms.
  • Total Stopping Time (T): 20 ms + 154 ms = 174 ms (0.174 s).
  • Penetration Factor (C): For 14 mm resolution, C = 8 × (14 - 14) = 0 mm.
  • Initial Calculation at K = 2000 mm/s: S = (2000 × 0.174) + 0 = 348 mm.
  • ISO 13855 Rule Check: Since 348 mm ≤ 500 mm, K cannot be lowered to 1600 mm/s. The light curtain must be positioned at an exact physical distance of ≥ 348 mm from the pinch point.
Formula & factors cross-checked against BS EN ISO 13855:2010. Free of black-box approximations.
Optical Reset & Whole-Body Access Safeguard:If an operator can step entirely between the light curtain detection plane and the hazard zone, optical trip alone is insufficient. Secondary horizontal safeguarding beams, safety laser scanners, or a manual latching reset button outside the danger zone are mandatory under BS EN ISO 13855.

Statutory Standards: BS EN ISO 13855:2010 Section 6.2 • BS EN ISO 13857:2019 Table 2 • BS EN 60204-1:2018 • PUWER 1998 Regulation 11

Sparks Switchboard
Quick: