Calculators & Engineering Engines
First-principles electrical engineering calculators with transparent step-by-step mathematical working. Built for UK electrical contractors, consulting engineers, panel builders, and duty holders.
No matching tools found
Try searching for a different standard, keyword, manufacturer, or parameter.
The Core 6 Circuit Engines
Everyday workhorse calculators for statutory cable sizing, maximum Zs, voltage drop, and protective bonding.Cable Sizing & Derating Engine
Calculate minimum required cable current carrying capacity (Iz) applying ambient temperature, grouping, insulation, and protective device derating.
Voltage Drop Calculator
Calculate circuit voltage drop from first principles using tabulated mV/A/m values, line length, design current, and power factor cos φ.
Adiabatic / CPC Thermal Check
Verify circuit protective conductor (CPC) cross-sectional area under fault conditions using adiabatic equations and energy let-through tables.
Maximum Demand & Diversity Sizer
Calculate domestic and commercial maximum demand applying IET On-Site Guide Table A1 diversity rules and DNO cut-out headroom.
Maximum Zs & Loop Lookup
Tabulated maximum earth fault loop impedance (Zs) for MCBs, RCBOs, and fuses with instant 80% temperature correction rule calculation.
Earthing & Main Bonding Sizer
Calculate minimum circuit protective conductor (CPC) sizing via Table 54.7 and main protective bonding for PME (Table 54.8) and TN-S/TT installations.
Industrial, Motors & Renewable Sizing Engines (24)
Engineered solvers for motor starting, transformer protection, EV dynamic load management, and arc flash.Conduit & Trunking Capacity Sizer
Calculate minimum steel/PVC conduit diameter and trunking space factor (45% capacity) for mixed cable singles under BS 7671 Appendix 5.
24V DC Control Cable & Voltage Drop Sizer
Size DC conductors for industrial PLC I/O loops, sensors, and 24V field distribution ensuring loop voltage remains above operational dropout thresholds.
11kV Transformer IDMT Protection Sizer
Calculate IEC 60255 IDMT relay tripping times (SI, VI, EI) and verify the 0.35s discrimination grading margin between 11kV relays and 400V incomers.
Motor Full Load & Starting Current
Compute full load current (FLC), locked-rotor inrush peaks, and recommended thermal overload and backup fuse ratings across 0.37 kW to 315 kW motors.
DOL Motor Starter & Feeder Sizer
Size Direct-On-Line contactors (AC-3/AC-3e), thermal overloads, BS 88-2 gM fuses, BS 7671 feeder cables, and BS EN 61439-2 Form 4 MCC starter buckets.
Motor Starting Inrush & Voltage Dip Sizer
Calculate starting inrush current, cable voltage drop, and starting torque reduction across DOL, Star-Delta, Soft-Starter, and VFD regimes.
Motor Soft Starter Inrush & Ramp Sizer
Calculate reduced starting current, acceleration ramp time, and thyristor heat dissipation for pumps, compressors, and high-inertia conveyors.
Solar PV & Battery Storage: G98 vs G99 Sizer
Determine whether UK solar PV and battery storage qualifies for G98 Fit & Notify or requires G99 prior approval, evaluating AC coupling and G100 limits.
Commercial Solar PV, Battery (BESS) & EV Sizer
Size commercial solar arrays and BESS storage for EV fleets. Classify statutory DNO pathways (G98 vs G99) and G100 export schemes.
Standby & Prime Generator Sizing
Determine minimum standby/prime generator rating factoring in step-loading motor inrush, alternator subtransient reactance, and voltage dips.
1 MW Generator & Heavy Pumping Sizer
Calculate 1 MW generator step-loading, voltage dips, earth cable sizing (BS 7671 Table 54.7), starter torque curves, and circuit discrimination.
EV Charging & Open-PEN Earthing Sizer
Verify 100% continuous duty EV cable sizing, volt drop, and broken supply PEN touch voltage to evaluate Reg 722.411.4.1 compliance.
Commercial EV Dynamic Load Management Sizer
Model dynamic EV fleet curtailment waterfalls, building supply headroom, and phase balancing under BS 7671 Section 722.
Harmonic Derating & Neutral Sizing
Calculate neutral conductor heating, Table 4A3 derating factor Ch, and shift sizing bottlenecks to the neutral conductor under non-linear loads.
Harmonic Mitigation & EREC G5/5 Sizer
Calculate harmonic distortion, BS 7671 Table 4Aa triplen neutral sizing, PFC parallel resonance risk, and ENA EREC G5/5 Stage 1 compliance.
Machinery Functional Safety PL Sizer
Evaluate required Performance Level (PLr) via the ISO 13849-1 risk graph and verify achieved PL across Categories B-4, MTTFd, and DCavg.
Machinery Safety Distance & Light Curtain Sizer
Calculate minimum safety distances for optical light curtains, two-hand controls, and perimeter barrier reach-over distances under BS EN ISO 13855.
Fault Finding & Safe Isolation Engine
Interactive step-by-step troubleshooting decision tree for GS38 safe isolation, RCD nuisance tripping, high loop impedance, and neutral-earth faults.
Van Mode On-Site Quick Reference
High-contrast, plant-room offline quick reference for site sparks: instant 80% Max Zs lookup, cable current capacity, and BPG 4 EICR defect coding.
Searchable EICR Defect Finder
Searchable database of 40+ classified condition report defect scenarios with 1-click clipboard copy of compliant wording for test certificates.
Arc Flash Incident Energy & UK PPE Sizer
Calculate incident energy (cal/cm²), arc flash boundary, and BS EN 61482-1-1 ELIM/ATPV protective clothing tiers for 400V and 11kV switchgear.
VFD Pump & Fan Energy Savings
Calculate kilowatt-hour savings, payback periods, and carbon abatement achieved by replacing mechanical dampers and valves with variable speed drives.
Equipment Running Cost Calculator
Calculate hourly, monthly, and annual operational electricity costs for machinery, motors, and commercial loads with duty-cycle adjustments.
3-Phase Power & Current Converter
Instantly convert between kW, kVA, horsepower, and phase current for single-phase (230V) and three-phase (400V) systems with power factor compensation.
Field Reference Instruments & Syllabuses (4)
Print-ready inspection sheets, qualification syllabuses, and statutory trade dictionaries.C&G 2365 / 5357 Electrical Science 3D Hub
Complete syllabus mapping for Unit 202 and 302 linked to our 17 interactive 3D WebGL physics simulations. Includes 1-click VLE iframe embed snippets.
Pocket Electrical Cheat Sheets
Instant on-site lookups for BS EN 60529 IP ratings, Section 701 Bathroom Zones (2.5m socket limit), Earthing systems, and Table 41.1 disconnection times.
Printable Field Checklists (A4)
A4 print-ready inspection sheets: HSE GS38 10-Step Safe Isolation procedure, Minor Works test schedule, Emergency Lighting log, and Motor QC sheet.
Standards & Trade Jargon Buster
Directory of UK statutory enactments (EAWR, PUWER, DSEAR), designated standards (BS EN 60204-1, BS EN 61439), and searchable electrical trade dictionary.
Multi-Circuit Distribution Board Schedules & A4 PDF Submittals
Need to bundle circuits C1 through C36 with automatic submain voltage drop cascade, Ze/PFC inheritance, and client-ready compliance documentation? Generate audit-proof calculation schedules certified to BS 7671:2018+A4:2026.
Educational & Statutory Disclaimer
These calculation engines and reference instruments are published as educational and engineering reference aids for preliminary screening and BS 7671 methodology checks. They do not constitute formal installation design sign-offs or specifications. All calculations must be independently checked against project cable schedules, discrimination studies, and site environment surveys by a qualified and competent electrical engineer prior to procurement or installation (EAWR 1989 Regulation 16). Nothing in this guidance excludes or limits liability for death or personal injury caused by negligence, or any other liability which cannot be excluded or limited under UK law (including the Consumer Rights Act 2015 and Unfair Contract Terms Act 1977).