Core circuit engines

The Core 6 Circuit Engines

Everyday workhorse calculators for statutory cable sizing, maximum Zs, voltage drop, and protective bonding.
Conductor SizingIz / mm² SWA

Cable Sizing & Derating Engine

Calculate minimum required cable current carrying capacity (Iz) applying ambient temperature, grouping, insulation, and protective device derating.

BS 7671 DesignΔV / mV·A⁻¹·m⁻¹

Voltage Drop Calculator

Calculate circuit voltage drop from first principles using tabulated mV/A/m values, line length, design current, and power factor cos φ.

Thermal Stressk²S² ≥ I²t

Adiabatic / CPC Thermal Check

Verify circuit protective conductor (CPC) cross-sectional area under fault conditions using adiabatic equations and energy let-through tables.

Installation SizingReg 311.1 / OSG A1

Maximum Demand & Diversity Sizer

Calculate domestic and commercial maximum demand applying IET On-Site Guide Table A1 diversity rules and DNO cut-out headroom.

Fault ProtectionZs ≤ 0.8 · Zs(tab)

Maximum Zs & Loop Lookup

Tabulated maximum earth fault loop impedance (Zs) for MCBs, RCBOs, and fuses with instant 80% temperature correction rule calculation.

Conductor SizingTable 54.7 • 54.8 • Adiabatic

Earthing & Main Bonding Sizer

Calculate minimum circuit protective conductor (CPC) sizing via Table 54.7 and main protective bonding for PME (Table 54.8) and TN-S/TT installations.

Specialised engines

Industrial, Motors & Renewable Sizing Engines (24)

Engineered solvers for motor starting, transformer protection, EV dynamic load management, and arc flash.
Containment SizingΣF ≤ Enclosure

Conduit & Trunking Capacity Sizer

Calculate minimum steel/PVC conduit diameter and trunking space factor (45% capacity) for mixed cable singles under BS 7671 Appendix 5.

Control Systems24V PELV / SELV

24V DC Control Cable & Voltage Drop Sizer

Size DC conductors for industrial PLC I/O loops, sensors, and 24V field distribution ensuring loop voltage remains above operational dropout thresholds.

Substation ProtectionΔt ≥ 0.35s / IEC Curves

11kV Transformer IDMT Protection Sizer

Calculate IEC 60255 IDMT relay tripping times (SI, VI, EI) and verify the 0.35s discrimination grading margin between 11kV relays and 400V incomers.

Machinery EngineeringFLC · Inrush ×8.4

Motor Full Load & Starting Current

Compute full load current (FLC), locked-rotor inrush peaks, and recommended thermal overload and backup fuse ratings across 0.37 kW to 315 kW motors.

Motor Control & MCCAC-3e / Class 10/20

DOL Motor Starter & Feeder Sizer

Size Direct-On-Line contactors (AC-3/AC-3e), thermal overloads, BS 88-2 gM fuses, BS 7671 feeder cables, and BS EN 61439-2 Form 4 MCC starter buckets.

Motor DynamicsIstart / ΔV Dip %

Motor Starting Inrush & Voltage Dip Sizer

Calculate starting inrush current, cable voltage drop, and starting torque reduction across DOL, Star-Delta, Soft-Starter, and VFD regimes.

Motor ControlSCR 300% FLC

Motor Soft Starter Inrush & Ramp Sizer

Calculate reduced starting current, acceleration ramp time, and thyristor heat dissipation for pumps, compressors, and high-inertia conveyors.

Renewables & Storage16A / Phase Limit • ENA G98/G99

Solar PV & Battery Storage: G98 vs G99 Sizer

Determine whether UK solar PV and battery storage qualifies for G98 Fit & Notify or requires G99 prior approval, evaluating AC coupling and G100 limits.

Renewables & StorageG98/G99 / G100 Failsafe

Commercial Solar PV, Battery (BESS) & EV Sizer

Size commercial solar arrays and BESS storage for EV fleets. Classify statutory DNO pathways (G98 vs G99) and G100 export schemes.

Standby PowerkVA · ΔV ≤ 15%

Standby & Prime Generator Sizing

Determine minimum standby/prime generator rating factoring in step-loading motor inrush, alternator subtransient reactance, and voltage dips.

Standby & Heavy Pumping1MW Gen · ISO 8528

1 MW Generator & Heavy Pumping Sizer

Calculate 1 MW generator step-loading, voltage dips, earth cable sizing (BS 7671 Table 54.7), starter torque curves, and circuit discrimination.

EV InfrastructureSec 722 / O-PEN

EV Charging & Open-PEN Earthing Sizer

Verify 100% continuous duty EV cable sizing, volt drop, and broken supply PEN touch voltage to evaluate Reg 722.411.4.1 compliance.

EV InfrastructureSection 722 / DLM Waterfall

Commercial EV Dynamic Load Management Sizer

Model dynamic EV fleet curtailment waterfalls, building supply headroom, and phase balancing under BS 7671 Section 722.

Power QualityCh / Table 4A3

Harmonic Derating & Neutral Sizing

Calculate neutral conductor heating, Table 4A3 derating factor Ch, and shift sizing bottlenecks to the neutral conductor under non-linear loads.

Power QualityTHDi • G5/5 • Table 4Aa

Harmonic Mitigation & EREC G5/5 Sizer

Calculate harmonic distortion, BS 7671 Table 4Aa triplen neutral sizing, PFC parallel resonance risk, and ENA EREC G5/5 Stage 1 compliance.

Machinery SafetyPLr / Cat B-4 / MTTFd

Machinery Functional Safety PL Sizer

Evaluate required Performance Level (PLr) via the ISO 13849-1 risk graph and verify achieved PL across Categories B-4, MTTFd, and DCavg.

Optical SafeguardingS = (K · T) + C

Machinery Safety Distance & Light Curtain Sizer

Calculate minimum safety distances for optical light curtains, two-hand controls, and perimeter barrier reach-over distances under BS EN ISO 13855.

Inspection & TestingGS38 • RCD • Zs • N-E

Fault Finding & Safe Isolation Engine

Interactive step-by-step troubleshooting decision tree for GS38 safe isolation, RCD nuisance tripping, high loop impedance, and neutral-earth faults.

Mobile Field Tool80% Zs / Iz / BPG4

Van Mode On-Site Quick Reference

High-contrast, plant-room offline quick reference for site sparks: instant 80% Max Zs lookup, cable current capacity, and BPG 4 EICR defect coding.

Inspection & TestingBPG4 • C1/C2/C3/FI

Searchable EICR Defect Finder

Searchable database of 40+ classified condition report defect scenarios with 1-click clipboard copy of compliant wording for test certificates.

High Voltage & Arc Flashcal/cm² / AFB / BS EN 61482

Arc Flash Incident Energy & UK PPE Sizer

Calculate incident energy (cal/cm²), arc flash boundary, and BS EN 61482-1-1 ELIM/ATPV protective clothing tiers for 400V and 11kV switchgear.

Energy OptimizationAffinity P ∝ N³

VFD Pump & Fan Energy Savings

Calculate kilowatt-hour savings, payback periods, and carbon abatement achieved by replacing mechanical dampers and valves with variable speed drives.

Commercial Ops£ / Annum • Duty %

Equipment Running Cost Calculator

Calculate hourly, monthly, and annual operational electricity costs for machinery, motors, and commercial loads with duty-cycle adjustments.

Rapid CalculationskW ⇄ kVA ⇄ Amps

3-Phase Power & Current Converter

Instantly convert between kW, kVA, horsepower, and phase current for single-phase (230V) and three-phase (400V) systems with power factor compensation.

Field references

Field Reference Instruments & Syllabuses (4)

Print-ready inspection sheets, qualification syllabuses, and statutory trade dictionaries.
College VLE & ApprenticesC&G 2365 / 5357

C&G 2365 / 5357 Electrical Science 3D Hub

Complete syllabus mapping for Unit 202 and 302 linked to our 17 interactive 3D WebGL physics simulations. Includes 1-click VLE iframe embed snippets.

Rapid LookupIP • Sec 701 • 41.1

Pocket Electrical Cheat Sheets

Instant on-site lookups for BS EN 60529 IP ratings, Section 701 Bathroom Zones (2.5m socket limit), Earthing systems, and Table 41.1 disconnection times.

Field TemplatesHSE GS38 • Minor Works

Printable Field Checklists (A4)

A4 print-ready inspection sheets: HSE GS38 10-Step Safe Isolation procedure, Minor Works test schedule, Emergency Lighting log, and Motor QC sheet.

Terminology & LawA to Z Directory • DSEAR

Standards & Trade Jargon Buster

Directory of UK statutory enactments (EAWR, PUWER, DSEAR), designated standards (BS EN 60204-1, BS EN 61439), and searchable electrical trade dictionary.

Multi-circuit schedules

Multi-Circuit Distribution Board Schedules & A4 PDF Submittals

Need to bundle circuits C1 through C36 with automatic submain voltage drop cascade, Ze/PFC inheritance, and client-ready compliance documentation? Generate audit-proof calculation schedules certified to BS 7671:2018+A4:2026.

BS 7671:2018+A4:2026 Verified 100% Offline Private Storage

Educational & Statutory Disclaimer

These calculation engines and reference instruments are published as educational and engineering reference aids for preliminary screening and BS 7671 methodology checks. They do not constitute formal installation design sign-offs or specifications. All calculations must be independently checked against project cable schedules, discrimination studies, and site environment surveys by a qualified and competent electrical engineer prior to procurement or installation (EAWR 1989 Regulation 16). Nothing in this guidance excludes or limits liability for death or personal injury caused by negligence, or any other liability which cannot be excluded or limited under UK law (including the Consumer Rights Act 2015 and Unfair Contract Terms Act 1977).